TABLE-I
APPLICABLE CODES AND STANDARDS (FOR ELECTRICAL SYSTEMS)
Sl No.
|
IS No.
|
DESCRIPTION
|
|
1.0
|
Low
Voltage switchgear :
|
||
1.1
|
IS 5 : 1995
|
Colours for ready mixed paints and enamels.
|
|
1.2
|
IS 8623 Part I:1993
|
Low voltage switchgear and controlgear
assemblies. Requirements for type tested and partially type tested assemblies.
|
|
1.3
|
IS 8828 : 1993
|
Electrical accessories – Circuit breaker for
overcurrent protection for household and installation.
|
|
1.4
|
IS 10118
Part 1: 1982
Part 2: 1982
Part 3: 1982
Part 4: 1982
|
Code of practice for selection, installation and
maintenance of switchgear and controlgear
General
Selection
Installation
Maintenance
|
|
1.5
|
IS 13947
Part 1: 1993
Part 2: 1993
Part 3: 1993
Part 4: 1993
Part 5: 1993
|
Low voltage switchgear and
controlgear: General rules -
Circuit breaker
Switches, disconnectors, switch disconnectors and fuse combination
units
Electromechanical
contactors and motor starters
Control circuit devices and
switching elements
|
|
2.0
|
Cabling system
|
||
2.1
|
IS 3961 (Part 5) :
1968
|
Recommended
current ratings for cables : PVC insulated light duty cables.
|
|
2.2
|
IS 3975 : 1988
|
Mild steel wires, formed
wires and tapes for armouring of cables.
|
|
2.3
|
IS 4826 : 1979
|
Hot dip galvanized coating
on round steel wires.
|
|
2.4
|
IS 5831 : 1984
|
PVC insulation and sheath
of electric cables.
|
|
2.5
|
IS 6380 : 1984
|
Elastomeric insulation and
sheath of electric cables.
|
|
2.6
|
IS 6474 :1984
|
Polyethylene insulation and
sheath of electric cables.
|
|
2.7
|
IS 7098 :1988
|
Cross linked polyethylene
insulated PVC sheathed cables.
|
|
2.8
|
IS 8130 :1984
|
Conductors for insulated
electric cables and flexible cords.
|
|
2.9
|
IS 9968 :1988
|
Elastomer insulated cables
: For working voltages upto and including 1100 V.
|
|
2.10
|
IS : 1554 Part I, II
|
PVC insulated cables
|
|
2.11
|
IS : 5819 – 1970
|
Recommended short circuit
rating for PVC cables
|
|
2.12
|
IS : 10810
|
Specification for testing
of cables
|
|
3.0
|
Earthing and lightning
protection system
|
|
3.1
|
IS : 3043 – 1987
|
Code of practice for
earthing.
|
3.2
|
IS : 2309 – 1989
|
Protection of buildings and
allied structures against Lightning – Code of practice.
|
3.3
|
IEEE Std. 80 : 1986
|
Guide for safety in alternating current substation grounding.
|
4.0
|
Lighting system
|
|
4.1
|
IS 1293 : 1988
|
Plug and socket outlets of
rated voltages upto and including 250 volts and rated currents upto and
including 16A.
|
4.2
|
IS 1534 : 1977
|
Ballast for fluorescent
lamps for switch start circuits.
|
4.3
|
IS 1569 : 1976
|
Capacitors for use in
tubular fluorescent high pressure mercury, low pressure mercury, low pressure
sodium vapour discharge lamp circuits.
|
4.4
|
IS 1258 : 1987
|
Bayonet lamp holders.
|
4.5
|
IS 418 : 1978
|
Tungsten filament general
service electric lamps.
|
4.6
|
IS 1777 : 1978
|
Industrial luminaire with
metal reflectors.
|
4.7
|
IS 1913 : 1978 Part 1
|
General and safety
requirements for luminaires – Tubular fluorescent lamps.
|
4.8
|
IS 2215 : 1983
|
Starters for fluorescent
lamps.
|
4.9
|
IS 2418 : 1977
|
Tubular fluorescent lamps
for general lighting service requirements and tests.
|
4.10
|
IS 3323 : 1980
|
Bi-pin lamp holders for
tubular fluorescent lamps.
|
4.11
|
IS 3324 : 1982
|
Holders for starters for
tubular fluorescent lamps.
|
4.12
|
IS 3646 : 1992 – Part 1
|
Code of practice for
interior illumination, general requirements and recommendation for working
interiors.
|
4.13
|
IS 3646 : 1966 – Part 2
|
Schedule of illumination
and glare index.
|
4.14
|
IS 3646 : 1968 – Part 3
|
Calculation of coefficient
of utilization by BZ method.
|
4.15
|
IS 5077 : 1969
|
Decorative lighting
outfits.
|
4.16
|
IS 6665 : 1972
|
Code of practice for
industrial lighting.
|
4.17
|
IS 7027 : 1984
|
Transistorised ballasts for
fluorescent lamps.
|
4.18
|
IS 7569 : 1987
|
Cast acrylic sheets for use
in luminaries.
|
4.19
|
IS 9974 : 1981
|
High pressure sodium vapour
lamps.
|
4.20
|
IS 10322
Part 1 : 1982
Part 2 : 1982
Part 3 : 1984
Part 4 : 1984
|
Luminaires
General requirements.
Construction requirements.
Screw and screwless
terminals.
Method of test.
|
4.21
|
IS 732 : 1989
|
Code of practice for
electric wiring installations.
|
5.0
|
Motors
|
|
5.1
|
IS - 325 : 1996
|
Specifications for 3-phase
induction motors.
|
5.2
|
IS - 4722
|
Rotating electric machines.
|
5.3
|
IS – 9283
|
Motors for submersible pumpsets.
|
5.4
|
IS – 6362
|
Designation of methods of
cooling for rotating electrical machinery.
|
5.5
|
IS 12615 : 1996
|
Specification for
energy-efficient induction motors.
|
5.6
|
IEC – 37
|
Specifications for Canned
rotor pump motor set.
|
5.7
|
IEEE – 252
|
Specifications for Canned
rotor pump motor set.
|
6.
|
IS : 4666
|
Electric passenger and
goods elevators.
|
7.
|
IS 11171 : 1985
|
Dry type power
transformers.
|
8.
|
IS 12661 : 1988
|
High voltage motor
starters (full voltage) ac starters.
|
9.
|
IS 1652 : 1984
|
Stationary cells and
batteries lead-acid type (with plante positive plates).
|
10.
|
ISO 3046
|
Diesel generator sets.
|
11.
|
IEEE 485
|
Recommendations for sizing
large lead acid storage batteries for generating stations and substations.
|
12.
|
IS 1893 : 1999
|
Criteria for Earthquake
resistant design of structures.
|