Q101. How the supply is provided in cells for a special maintenance
work?
A. Power supply in the
cell is provided through extension boards.
Q102. What is the power supply arrangement for fuel pond lights
which are normally under water?
A. Power supply to fuel
pond lights is given through 440/110 VAC, isolated transformer.
Q103. How the supply is provided for sampling blister?
A. Power supply 230/32 VAC, isolation
transformer for halogen lamps and 230 V for HPMV lamps through starter.
Q104. What are the power supply sources for emergency lights?
A. Emergency lights are
fed from MP – 15.
Q105. What is the procedure for taking up such a special work of
pond light?
A. Pond light are removed out of pond. Then
they are decontaminated and then they are repaired as per SWP instruction.
Q106. How do you disconnected the light? What extra care is needed
to enter inside the fuel pond while
disconnecting and
connecting?
A.
For disconnecting pond lights, switch off the supply to isolation
transformer, remove fuses. Disconnected the joints, tape cable ends, safety
belts are to be used while disconnecting and connecting the lights.
Q107. When the light is lifted out of the pond? Why it is necessary
to spray DM water?
A. When pond light fixtures are taken out of the
pond DM water is sprayed on it for decontamination of fixture.
Q108. What precautions are to be taken while opening the blister
plugs?
A. Ensure that BOG fan is
running while opening blister plug otherwise air activity will come out. Plug
also wedge for blister cover.
Q109. Why the power cable entry in the blister is zigzag?
A. Blisters are under
vacuum. Zigzag cable entry prevents the thrust of pressured air entry into
blister.
Q110. What care is to be taken to prevent the overheating of blister
by the lamp?
A. To switch off blister lights, timers are
provided in light circuit. Switch cut off the supply of light after preset time
and avoids overheating of blister. This timers are also increasing the life of
bulbs.
Q111. How the lamps are
protected from being damaged by the tong?
A. A SS grill is
provided on lamps for protecting it from tongs.
Q112. What safety care is to be taken while giving power supply to
these lamps?
A. Supply voltage should be checked before
giving power supply to these lamps because there are two supply i.e. 230VAC
& 32VAC.
Q113. What is the procedure
for removing the light plug from the Dissolver cell?
A. Plug can be replaced by removing the block
out side before this supply should switched off and DOG should be running to keep dissolver cell at low pressure.