Q74. What procedure is followed for disposing waste bags?
A. Waste bags should be
sealed properly. Then it should be disposed in waste transit area.
Q75. What will you do if criticality monitor gives alarm?
A. If criticality alarm is there then one
should come out of plant immediately with shortest route without using lift
keeping handkerchief on nose and has to gather in Low block near entrance hall
and to report supervisor.
Q76. Describe all health physics instruments.
A. Portable Monitor, Hand monitor, CAM – Beta,
Pu counting monitor, Area Gamma monitor, WRGM (wide range Gamma monitor),
Criticality monitor, Survey monitor, Tele-detector, Beta dose-rate meter, Alpha
& Beta counting system, Dosimeter, TLD.
Q77. What does a tag on waste bag indicate?
A. Tag has numbersRHC-5,
RHC-6, RHC-7.
RHC – 5
|
WHITE TAG
|
Less than 20 mr/hr, Beta & Gamma
|
RHC – 6
|
YELLOW TAG
|
20 to 200 mr/hr, Beta & Gamma
|
RHC - 7
|
PINK TAG
|
More than 200 mr/hr, High Alpha
|
Q78. How maintenance waste is packed?
A. As per answer of Q.74
Q79. How liquid waste is handled?
A.
High activity liquid is
shielded in lead cask for low activity, it is kept in carboy, PVC bag, proper
tag is provided by HP. It is also handled as per instruction of HP.
Q80. How will get adequate decontamination of liquid spill?
A. Moping of liquid from low activity area to
high activity area is done by using water and detergent till contamination is
coming up to permissible level.
Q81. If TLD of worker falls
in radiation area, what will you do?
A. TLD loss will be
immediately reported to HP.
Q82. Why monitor are placed
on condensate headers?
A. Monitors are placed at steam condensate
headers for detecting accidental release of activity to the condensate. EJC – GM are placed to detect failure of evaporator.
Q83. What action is to be
taken if this monitor gives alarm?
A.
Steam pushing through condensate headers should be stopped. Individual
are monitored for contamination and replaced. Also the transfer of liquid
wasted to HUT should be stopped, faulty equipment is to be isolated.
Q84. What is CRPC panel? What
does it show?
A. CRPC:
Central Radiation Protection Console. It gives radiation level and air
activity level in specified area. Panel is located in control room. (Gamma
monitor, CAM , Criticality monitor)
Q85. What is the specialty in
the light fittings that they are not manufactured in India ?
A. These fittings are water tight and glass
fittings can withstand water pressure. These are provided on 110V supply which
is safe compared to 230 V.
Q86. How the lamp is prevented
from the reaction of contaminated water?
A. As the lamp fixture is
water tight, contaminated water cannot enter in the fixture.
Q87. How the halogen lamp is
cooled?
A. Heat generated by the halogen lamp is
absorbed by the metallic fixture and it is absorbed by pond water.
Q88. Can the lamp be removed
out of the fuel pond when it is in ON position?
A. Pond light cannot be
removed out of the fuel pond when it is in ON position.
Q89. What sort of lamps are used in radioactive liquid sampling
blister?
A. There are two types of
lamps. 1. Halogen, 2. HPMV.
Q90. What are the supply voltage and capacity of these lights?
A. 1. Halogen – 250 W, 32 V
2. HPMV – 125 W, 250 V.
Q91. At what height the aviation lights are situated?
A. Aviation lights are
situated at top stage 125 mtrs, third stage 95 mtrs & Second stage 65 mtrs.
Q92. What is the supply
voltage?
A. 230 VAC.
Q93. How these lights are
controlled automatically?
A. These lights are
operated by photocell.
Q94. How many lights are
there totally?
A. 18 lights (9 fixtures
containing 2 lights in each)
Q95. What is the necessity of
these lights?
A. These are aviation
signal lights.
Q96. What type of
illumination is provided in dissolver cell?
A. HPMV lamps are used in
dissolver cell for illumination.
Q97. How the light is mounted
inside the cell?
A. Fixtures are amounted on cell wall on the
blocks which can be removed for bulb replacement / rectification.
Q98. Can the radioactivity seen
through these light fittings?
A. No.
Q99. How these lights
rectified?
A. Lights can be
rectified by removing the holder blocks.
Q100. Are there any power point, inside the cell?
A. No, there is not any
power point inside the cell.